اطلاعاتی درباره پکینگ های برج خنک کننده

۱۳۹۶/۰۳/۲۷

گام ۱۲
E.S.I -Pac 12 is a cross-fluted film fill media manufactured from rigid PVC sheets conforming to CTI STD-136 for cooling tower heat-transfer applications. The media is fabricated from corrugated PVC sheets that are solvent-welded for maximum strength and resistant to UV, rot, fungus, organic and inorganic solvents, acids, alkalis, and chemicals normally found in cooling tower waters

PVC SHEET PROPERTIES:

Physical Property ASTM Test Units Value
Density D772 g/cm3 ۱٫۳۹ – ۱٫۴۵
Tensile Strength (yield) D882 lb/in2 ۶,۰۰۰ min
Flexural Strength D790 lb/in2 >11,000
Flexural Modulus D790 lb/in2 >525,000
Stiffness in Flexure D747 lb/in2 ۵۲۵,۰۰۰ min
Gardner Impact Strength D4226 in lb/mil ۱٫۰ min
Tensile Impact Strength D1822 ft lb/in2 ۲۵۵ min
Heat Deflection D648 Deg F. ۲۵۵ min
Flammability D635 Self  extinguishing  Less than 5 seconds
Flame Spread Rate E 84 Less than 20

 

 

 

 

گام ۱۹

Modules are fabricated in 12″ and 24″ depths, 12″ to 24″ widths, and in lengths up to 12′-0″. Sheet spacing is 0.75″ (19mm). Heat-transfer area (wetted surface) is 48 ft2 per ft3. Standard PVC sheet mil thicknesses are 10 and 15 mil (after forming). Weight per cubic foot is approximately 1.8 lb/ft3 for 10-mil and approximately 2.6 lb/ft3 for 15-mil. Custom dimension modules and mil thicknesses are available upon request

PVC SHEET PROPERTIES:

Physical Property ASTM Test Units Value
Density D772 g/cm3 ۱٫۳۹ – ۱٫۴۵
Tensile Strength (yield) D882 lb/in2 ۶,۰۰۰ min
Flexural Strength D790 lb/in2 >11,000
Flexural Modulus D790 lb/in2 >525,000
Stiffness in Flexure D747 lb/in2 ۵۲۵,۰۰۰ min
Gardner Impact Strength D4226 in lb/mil ۱٫۰ min
Tensile Impact Strength D1822 ft lb/in2 ۲۵۵ min
Heat Deflection D648 Deg F. ۲۵۵ min
Flammability D635 Self extinguishing Less than 5 seconds
Flame Spread Rate E 84 Less than 20

 

.

 

 

 

گام ۱۹

Modules are fabricated in 12″, 24″ and 48” depths, 12” to 24” widths, and in lengths up to 12’-۰” in 2’ increments. Sheet spacing is 19mm and minimum heat transfer area (wetted surface) is 45 ft2/ft3. Standard PVC sheet mil thicknesses are 10 and 15 mil (after forming). Weight per cubic foot is approximately 1.6 lbs/ft3 for 10-mil packs and approximately 2.4 lbs/ft3 for 15-mil. Custom dimension modules and mil thicknesses are available upon request

PVC SHEET PROPERTIES:

Physical Property ASTM Test Units Value
Density D772 g/cm3 ۱٫۳۹ – ۱٫۴۵
Tensile Strength (yield) D882 lb/in2 ۶,۰۰۰ min
Flexural Strength D790 lb/in2 >11,000
Flexural Modulus D790 lb/in2 >525,000
Stiffness in Flexure D747 lb/in2 ۵۲۵,۰۰۰ min
Gardner Impact Strength D4226 in lb/mil ۱٫۰ min
Tensile Impact Strength D1822 ft lb/in2 ۲۵۵ min
Heat Deflection D648 Deg F. ۲۵۵ min
Flammability D635 Self extinguishing Less than 5 seconds
Flame Spread Rate E 84 Less than 20

 

 

 

 

گام ۳۰

Modules are fabricated in 12″, 24″ and 48″ depths, 12″ to 24″ widths, and in lengths up to 12′-0″. Sheet spacing is 1.20″ (30mm). Heat-transfer area (wetted surface) is 31 FT2 per FT3. Standard sheet mil thicknesses are 15 mil and 20 mil after forming. Custom dimension modules and mil thicknesses are available upon request

PVC SHEET PROPERTIES:

Physical Property ASTM Test Units Value
Density D772 g/cm3 ۱٫۳۹ – ۱٫۴۵
Tensile Strength (yield) D882 lb/in2 ۶,۰۰۰ min
Flexural Strength D790 lb/in2 >11,000
Flexural Modulus D790 lb/in2 >525,000
Stiffness in Flexure D747 lb/in2 ۵۲۵,۰۰۰ min
Gardner Impact Strength D4226 in lb/mil ۱٫۰ min
Tensile Impact Strength D1822 ft lb/in2 ۲۵۵ min
Heat Deflection D648 Deg F. ۲۵۵ min
Flammability D635 Self extinguishing Less than 5 seconds
Flame Spread Rate E 84 Less than 20

 